902P Portable pH/Conductivity/TDS/Salinity Meter Model Number: 902P

Specifications

 

Multiparameter portable pH/Conductivity meter includes 6 measurement modes. The meter is used for measuring the pH, ORP, Conductivity, TDS, Salinity and Resistivity of the liquids.

 

pH Mode:
? Multiparameter water quality meter is equipped with a large backlit LCD display.
? 1 to 5 points push-button calibration with auto-buffer recognition.
? Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
? Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
? Single point offset calibration allows adjusting the displayed value to a known standard.
? Relative and absolute millivolt measurement modes provide accurate ORP readings.

Conductivity/TDS/Salinity/Resistivity Mode:
? 1 to 5 points push-button calibration with automatic calibration solution recognition.
? Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion
  factor, seawater and practical salinity measurement modes.
? Linear or pure water compensation improves measurement accuracy of meter.

Other Features:
? Automatic Temperature Compensation provides accurate reading over the entire range.
? Calibration Due Reminder prompts user to calibrate the meter regularly.
? Stability indicator automatically shows current measurement status.
? Auto-Hold function freezes stable measured value for easy viewing and recording.
? Manual temperature calibration corrects temperature deviation.
? Selectable temperature unit (°C or °F) meets different application requirements.
? Automatic electrode diagnosis shows zero point offset and slope of the electrode.
? Help message as a operational guide that helps you quickly begin using the meter.
? System menu allows setting the 12 parameters, including the number of calibration points,
  resolution, stability condition, measurement units, etc.
? Reset feature automatically resumes all parameters back to factory default options.
? Expanded memory stores and recalls up to 500 readings.
? Built-in real-time clock stamps stored data to meet GLP standard.
? Stored data can be transferred into computer by USB communication interface.
? Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use
  the meter smoothly.

 

Specifications

Model

Bante902P

pH

Range

-2.000~20.000pH

Accuracy

±0.002pH

Resolution

0.1, 0.01, 0.001pH

Calibration Points

1 to 5 points

Calibration Solutions

USA, NIST, DIN or User-defined

Temperature Compensation

0~100°C, 32~212°F

Compensation Mode

Manual or Automatic

mV

Range

-1999.9~1999.9mV

Accuracy

±0.2mV

Resolution

0.1, 1mV

Calibration Points

1 point (Only for Relative mV mode)

Calibration Range

±200mV

Conductivity

Range

0~20.00, 200.0, 2000?S/cm, 20.00, 200.0mS/cm

Accuracy

±0.5% F.S

Calibration Points

1 to 5 points

Calibration Solutions

10?S/cm, 84?S/cm,1413?S/cm,12.88mS/cm,111.8mS/cm

Temperature Compensation

0~100°C, 32~212°F, Manual or Automatic

Temperature Coefficient

0.0~10.0%/°C

Compensation Modes

Linear or Pure Water

Cell Constant

K=0.1, 1, 10 or User-defined

Normalization Temperature

20°C or 25°C

TDS

Range

0~10ppt (Max. 20ppt, depending on factor setting)

Accuracy

±1% F.S

TDS Factor

0.1~1.0 (Default 0.5)

Salinity

Range

0~10ppt (Max. 80ppt)

Accuracy

±1% F.S

Measurement Modes

Seawater or Practical Salinity

Resistivity

Range

0~100MΩ

Accuracy

±1% F.S

Resolution

0.01, 0.1, 1

Temperature

Range

0~105°C, 32~221°F

Accuracy

±0.5°C, ±0.9°F

Resolution

0.1°C

Calibration Points

1 point

Calibration Range

Measured value ±10°C

Others

Hold Function

Manual or Automatic

Stability Conditions

Low or High

Calibration Due

0 to 31 days

Power Off

Manual or Automatic (10, 20, 30 minutes)

Reset Function

Yes

Memory

Stores up to 500 data sets

Output

USB Communication Interface

Connector

BNC, 6-pin Mini Plug

Power Requirements

3×1.5V "AA" Batteries

Battery Life

Approximately 150 hours (Turn off the backlit)

Dimensions

170(L)×85(W)×30(H)mm

Weight

300g

Order Information

Order Code

Accessories

Bante902P-CN

E201-BNC pH Electrode

CON-1 Conductivity Electrode

TP-10K Temperature Probe

pH Buffer Solutions (pH4.01/7.00/10.01)

Conductivity Standard Solutions (84?S, 1413?S, 12.88mS)

AA Battery

Carrying Case

Bante902P-UK

P11 Glass pH Electrode (Made in UK)

K10 Conductivity Electrode (Made in UK)

TP-10K Temperature Probe

pH Buffer Solutions (pH4.01/7.00/10.01)

Conductivity Standard Solutions (84?S, 1413?S, 12.88mS)

AA Battery

Carrying Case

 

Optional Accessories

Items

Description

P11 pH Electrode

For the general liquids

P11-LiCl pH Electrode

For the non-aqueous samples

P11-HA pH Electrode

For the photographic processing solutions

P11-NA pH Electrode

For the biofuel

P11-DW pH Electrode

For the low ionic strength samples

P12 pH Electrode

For the sample in the test tube

P13 pH Electrode

For the micro-volume samples

P14 pH Electrode

For the outdoor applications

P15 pH Electrode

For the low conductivity liquids

P16 pH Electrode

For the Tris buffers

P17 pH Electrode

For the semisolid samples (Flat Surface)

P18 pH Electrode

For the slurries

P19 pH Electrode

For the semisolid samples

P21 pH Electrode

For the colloids

P22 pH Electrode

For high temperature measurements

501 ORP Electrode

For the sample with strong redox potential

502 ORP Electrode

For the sample with weak redox potential

CON-0.1 Conductivity Electrode

For the pure water

CON-1 Conductivity Electrode

For the general liquids

CON-10 Conductivity Electrode

For the high conductivity liquids

Conductivity Standard Solutions

84?S/cm, 1413?S/cm, 12.88mS/cm, 111.8mS/cm

pH Buffer Pouches (USA)

pH4.01/7.00/10.01

pH Buffer Pouches (NIST)

pH4.01/6.86/9.18

TP-10K Temperature Probe

Special-purpose sensor

Packaging

Order Code

Dimensions

Weight

Bante902P-CN

475(L)×155(W)×350(H)mm

2kg

Bante902P-UK

475(L)×155(W)×350(H)mm

2kg

Language

Email to this supplier

Please fill the form carefully, and the columns marked with "*" are important. Thank you!

To: YeWei Chen

*Name:

*E-mail:

*Message:

Your message must be

I agree to share my
Business Card to the
supplier.Your message must
be between 20-8000
characters