Categories
900P Portable Multiparameter Water Quality Meter Model Number: 900P

Specifications

 

Multiparameter portable water quality meter includes the 8 measurement modes. The meter is suitable for measuring the pH, ORP, Ion concentration, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen of the liquids.

 

pH Mode:
? Multiparameter water quality meter is equipped with a large backlit LCD display.
? 1 to 5 points push-button calibration with auto-buffer recognition.
? Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
? Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
? Single point offset calibration allows adjusting the displayed value to a known standard.
? Relative and absolute millivolt measurement modes provide accurate ORP readings.

Ion Mode:
? 2 to 5 points calibration including the eight concentration calibration points can be selected.
? Automatically recognize ion selective electrodes, does not need to specify type of ion.
? Direct ion concentration readout simplifies the elaborate measurement process.
? Selectable multiple concentration units includes the ppm, mg/L, mmol/L and mol/L.

Conductivity/TDS/Salinity/Resistivity Mode:
? 1 to 5 points push-button calibration with automatic calibration solution recognition.
? Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion
  factor, seawater and practical salinity measurement mode.
? Linear or pure water compensation improves measurement accuracy of meter.

Dissolved Oxygen Mode:
? 1 or 2 points calibration using air-saturated water and zero oxygen solution.
? Manual salinity and barometric pressure compensation improve the measurement accuracy. 

Other Features:
? Automatic Temperature Compensation provides accurate reading over the entire range.
? Calibration Due Reminder prompts user to calibrate the meter regularly.
? Stability indicator automatically shows current measurement status.
? Auto-Hold function freezes stable measured value for easy viewing and recording.
? Manual temperature calibration corrects temperature deviation.
? Selectable temperature unit (°C or °F) meets different application requirements.
? Automatic electrode diagnosis shows zero point offset and slope of the electrode.
? Help message as a operational guide that helps you quickly begin using the meter.
? System menu allows setting the 15 parameters, including the number of calibration points,
  resolution, stability condition, measurement units, etc.
? Reset feature automatically resumes all parameters back to factory default options.
? Expanded memory stores and recalls up to 500 readings.
? Built-in real-time clock stamps stored data to meet GLP standard.
? Stored data can be transferred into computer by USB communication interface.
? Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use
  the meter smoothly.

 

Specifications

Model

Bante900P

pH

Range

-2.000~20.000pH

Accuracy

±0.002pH

Resolution

0.1, 0.01, 0.001pH

Calibration Points

1 to 5 points

Calibration Solutions

USA, NIST, DIN or User-defined

Temperature Compensation

0~100°C, 32~212°F

Compensation Mode

Manual or Automatic

mV

Range

-1999.9~1999.9mV

Accuracy

±0.2mV

Resolution

0.1, 1mV

Calibration Points

1 point (Only for Relative mV mode)

Calibration Range

±200mV

Ion

Range

0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)

Accuracy

±0.5% F.S (Monovalent), ±1% F.S (Divalent)

Resolution

0.001, 0.01, 0.1, 1

Calibration Points

2 to 5 points

Calibration Solutions

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L

Temperature Compensation

0~100°C, 32~212°F

Compensation Mode

Manual or Automatic

Conductivity

Range

0~20.00, 200.0, 2000?S/cm, 20.00, 200.0mS/cm

Accuracy

±0.5% F.S

Calibration Points

1 to 5 points

Calibration Solutions

10?S/cm, 84?S/cm,1413?S/cm,12.88mS/cm,111.8mS/cm

Temperature Compensation

0~100°C, 32~212°F, Manual or Automatic

Temperature Coefficient

0.0~10.0%/°C

Compensation Modes

Linear or Pure Water

Cell Constant

K=0.1, 1, 10 or User-defined

Normalization Temperature

20°C or 25°C

TDS

Range

0~10ppt (Max. 20ppt, depending on factor setting)

Accuracy

±1% F.S

TDS Factor

0.1~1.0 (Default 0.5)

Salinity

Range

0~10ppt (Max. 80ppt)

Accuracy

±1% F.S

Measurement Modes

Seawater or Practical Salinity

Resistivity

Range

0~100MΩ

Accuracy

±1% F.S

Resolution

0.01, 0.1, 1

Dissolved Oxygen

Range

0.00~20.00mg/L (or ppm)

Accuracy

±0.2mg/L

Resolution

0.01mg/L

Calibration Points

1 or 2 points

Temperature Compensation

0~50°C, 32~122°F, Automatic

Pressure Correction

60.0~112.5kPa, 450~850mmHg

Salinity Correction

0~50g/L

% Saturation of Oxygen

Range

0.0~200.0%

Accuracy

±2.0%

Resolution

0.1, 1%

Temperature

Range

0~105°C, 32~221°F

Accuracy

±0.5°C, ±0.9°F

Resolution

0.1°C

Calibration Points

1 point

Calibration Range

Measured value ±10°C

Others

Hold Function

Manual or Automatic

Stability Conditions

Low or High

Calibration Due

0 to 31 days

Power Off

Manual or Automatic (10, 20, 30 minutes)

Reset Function

Yes

Memory

Stores up to 500 data sets

Output

USB Communication Interface

Connector

BNC, 6-pin Mini Plug

Power Requirements

3×1.5V "AA" Batteries

Battery Life

Approximately 150 hours (Turn off the backlit)

Dimensions

170(L)×85(W)×30(H)mm

Weight

300g

Order Information

 

Optional Accessories

Order Code

Accessories

Bante900P-CN

E201-BNC pH Electrode

CON-1 Conductivity Electrode

DO100 Dissolved Oxygen Probe (Made in US)

TP-10K Temperature Probe

pH Buffer Solutions (pH4.01/7.00/10.01)

Conductivity Standard Solutions (84?S, 1413?S, 12.88mS)

DO Electrolyte Solution

DO Membrane Cap

AA Battery

Carrying Case

Bante900P-UK

P11 Glass pH Electrode (Made in UK)

K10 Conductivity Electrode (Made in UK)

DO100 Dissolved Oxygen Probe (Made in US)

TP-10K Temperature Probe

Items

Description

P11 pH Electrode

For the general liquids

P11-LiCl pH Electrode

For the non-aqueous samples

P11-HA pH Electrode

For the photographic processing solutions

P11-NA pH Electrode

For the biofuel

P11-DW pH Electrode

For the low ionic strength samples

P12 pH Electrode

For the sample in the test tube

P13 pH Electrode

For the micro-volume samples

P14 pH Electrode

For the outdoor applications

P15 pH Electrode

For the low conductivity liquids

P16 pH Electrode

For the Tris buffers

P17 pH Electrode

For the semisolid samples (Flat Surface)

P18 pH Electrode

For the slurries

P19 pH Electrode

For the semisolid samples

P21 pH Electrode

For the colloids

P22 pH Electrode

For high temperature measurements

501 ORP Electrode

For the sample with strong redox potential

502 ORP Electrode

For the sample with weak redox potential

Na-US Sodium Electrode

Range: 0.1~23000ppm

CL-US Chloride Electrode

Range: 1.8~35500ppm

F-US Fluoride Electrode

Range: 0.02ppm to Saturation

Ca-US Calcium Electrode

Range: 0.02~40000ppm

NO3-US Nitrate Electrode

Range: 0.4~62000ppm

Br-US Bromide Electrode

Range: 0.4 to 79900ppm

NH4-US Ammonium Electrode

Range: 0.1~18000ppm

Cn-US Cyanide Electrode

Range: 0.2~260ppm

Cd-US Cadmium Electrode

Range: 0.01~11200ppm

Cu-US Cupric Electrode

Range: 0.006~6400ppm

I-US Iodide Electrode

Range: 0.06~127000ppm

Pb-US Lead Electrode

Range: 0.2~20700ppm

Ag-US Silver Electrode

Range: 0.01~107900ppm

K-US Potassium Electrode

Range: 0.04~39000ppm

S-US Sulphide Electrode

Range: 0.003~32100ppm

NH3-US Ammonia Electrode

Range: 0.02~17000ppm

CON-0.1 Conductivity Electrode

For the pure water

CON-1 Conductivity Electrode

For the general liquids

CON-10 Conductivity Electrode

For the high conductivity liquids

DO100 Dissolved Oxygen Probe

Polarographic sensor

Conductivity Standard Solutions

84?S/cm, 1413?S/cm, 12.88mS/cm, 111.8mS/cm

Ion Standard Solutions

480mL/Bottle

Ionic Strength Adjusters

480mL/Bottle

DO Electrolyte Solution

480mL/Bottle

DO Membrane Cap

Special-purpose spare

pH Buffer Pouches (USA)

pH4.01/7.00/10.01

pH Buffer Pouches (NIST)

pH4.01/6.86/9.18

TP-10K Temperature Probe

Special-purpose sensor

Packaging

Order Code

Dimensions

Weight

Bante900P-CN

475(L)×155(W)×350(H)mm

2kg

Bante900P-UK

475(L)×155(W)×350(H)mm

2kg

Language

Email to this supplier

Please fill the form carefully, and the columns marked with "*" are important. Thank you!

To: YeWei Chen

*Name:

*E-mail:

*Message:

Your message must be

I agree to share my
Business Card to the
supplier.Your message must
be between 20-8000
characters