■ Characteristic for model BIII and BX
● Multiple data is displayed in the LCD screen at the same time, automatic recovery to previous status after power outage and recovery.
● Special function key for temperature setting.
● Auxiliary menus make over-temperature alarm, deviation adjust, and menu lock come true.
● Forced air convection makes the temperature more uniform.
● Power outage protector: automatic recovery to previous normal status after power on.
● Compressor overload protector.
■ Special characteristic for model BX
● 30 periods of programs LCD controller, gradient running.
● Shelf-check of the circuit, sensor fault alarm, and superior and inferior limit over temperature alarm.
● Intelligent refrigeration and defrosting system.
● Watchdog timer
● Over temperature protector.
Technical parameters | ||||
Model |
SPX-70BIII SPX-70BX |
SPX-150BIII SPX-150BX |
SPX-250BIII SPX-250BX |
|
Application | constant temperature experiment and environment experiment, water analysis, BOD test, bacteria and microorganism cultivation, plant breeding and cultivation, sample conservation( 0~65℃). | |||
Air circulation type | forced convection | |||
Performance | temp. range | 0~65℃ | ||
temp. resolution | 0.1℃ | |||
temp. fluctuation | high temperature: ±0.5℃; low temperature: ±0.1℃. | |||
temp. uniformity | ±1℃ | |||
Structure | chamber material | stainless steel | ||
shell material | spraying cold rolled steel | |||
thermal insulation material | PU | |||
heating device | stainless steel heating tube | |||
rated power | 0.7kw | 1.0kw | 1.4kw | |
compressor | Air-cooled hermetic compressor | |||
refrigerant | R134A | |||
defrosting system | model BIII: manual; model BX: automatic | |||
fairlead | φ52mm*1 on the left side of the body | |||
controlled external power supply | 1pc | |||
Controller | temp. control |
model BIII:1 period of program LCD,PID; model BX: 30 periods of programs LCD,PID. |
||
temp. setting | press the four keys slightly | |||
temp. display |
actual temp. is displayed by LCD (row 1); setting temp. is displayed by LCD (row 2). |
|||
timer | 0~9999 minutes (with timing function) | |||
operation function | model B: running with data set and time set, and automatic shut-down based on setting | |||
model BX: running with system set | ||||
program mode | model BIII: optional; model BX: standard configuration | |||
sensor | Pt100 | |||
additional function | model BIII: deviation adjustment, menu buttons lock, automatic recovery to previous status after power outage and recovery | |||
model BX: over temperature protector. watchdog timer, shelf-check of the circuit, intelligent refrigeration and defrosting system | ||||
Safety device |
model BIII: over-temperature alarm, overload protector; model BX: independent temperature limiter, shelf-check of the circuit. |
|||
Specification | working size (W*D*Hmm) | 420*350*500 | 500*400*750 | 500*500*950 |
exterior size (W*D*Hmm) | 570*560*1020 | 640*620*1270 | 660*700*1470 | |
packing size (W*D*Hmm) | 730*720*1170 | 820*760*1430 | 880*825*1645 | |
working capacity | 70L | 150L | 250L | |
shelf load bearing | 15kg | |||
max shelf layer | 5 layers | 9 layers | 12 layers | |
height between shelves | 60mm | |||
Power source (50/60Hz) /Rated current |
AC220V/2.3A | AC220V/3.6A | AC220V/5.5A | |
NW/GW | 69/92jg | 86/114kg | 100/139kg | |
Accessory | shelf | 2pcs | ||
shelf bracket | 4pcs | |||
Optional device | shelf, RS485 port, printer, recorder, external communication, remote control, program temperature controller, wireless message alert, U disk storage. |